HP ProCurve 2312 Switch

Aus /dev/tal
Version vom 17. Januar 2014, 22:10 Uhr von Omega (Diskussion | Beiträge) (Weiteres Vorgehen)

Wechseln zu: Navigation, Suche

Die Frage

  1. Kann man einen HP ProCurve 2312 Switch (J4817A) zu einem HP ProCurve 2512 Switch (J4812A) upgraden?

Vergleich der Spezifikationen

ProCurve 2312 Switch (J4817A) Ähnlichkeit ProCurve Switch 2512 (J4812A)
Technical features
External I/O ports 12 RJ-45 10/100 ports (IEEE 802.3 Type 10Base-T; 802.3u Type 100Base-TX) Yes check.svg.png 12 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
2 open transceiver slots Yes check.svg.png 2 open transceiver slots
1 RS-232C DB-9 download port Red x.svg.png 1 RS-232C DB-9 console port
Rack mounting Mounts in a standard 19 in. rack (hardware included) Yes check.svg.png Mounts in a standard 19 in. rack (hardware included)
Memory and Processor Packet buffer size: 6 MB shared packet buffers; RAM/ROM capacity: 26 MB; Processor type and speed: ARM7TDMI @ 62.5 MHz; Flash capacity: 2 MB Icon apps query.svg.png Processor type and speed: ARM7TDMI @ 62.5 MHz; Packet buffer size: 6 MB; RAM/ROM capacity: 26 MB; Flash capacity: 2 MB
Latency <10 µs (LIFO) Yes check.svg.png <10 µs (LIFO)
Address Table size 4,096 entries Yes check.svg.png 4,096 entries
routing/switching capacity 9.6 Gbps Yes check.svg.png 9.6 Gbps
throughput 4.8 mpps (64-byte packets) Yes check.svg.png 4.8 million pps (64-byte packets)
Management Features Red x.svg.png ProCurve Manager (included); ProCurve Manager Plus; command line interface; Web browser; configuration menu; out-of-band management; (serial RS-232C)
Communications IEEE 802.3x Flow Control Yes check.svg.png IEEE 802.3x Flow Control
Red x.svg.png RFC 3376 IGMPv1/v2/v3
Red x.svg.png IEEE 802.1D Spanning Tree
Red x.svg.png IEEE 802.1w Rapid Convergence Spanning Tree
Red x.svg.png IEEE 802.3ad Link Aggregation Control Protocol
Red x.svg.png RFC 1492 TACACS
Red x.svg.png IEEE 802.1X Network Login
Red x.svg.png IEEE 802.1Q VLANs
Red x.svg.png IEEE 802.1Q GVRP
Red x.svg.png IEEE 802.1p Priority SNMPv1/v2c
Red x.svg.png RFC 1493 Bridge MIB
Red x.svg.png RFC 1213 MIB II
Red x.svg.png RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
Red x.svg.png RFC 3164 Syslog; XRMON
Red x.svg.png RFC 2613 SMON; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
Power Requirements 100–127 VAC/200–240 VAC; 50/60 Hz Yes check.svg.png 100–127 VAC/200–240 VAC; 50/60 Hz
Power availability 2.4/1.2 A max Yes check.svg.png 2.4/1.2 A max
Power consumption 36W Yes check.svg.png 36W
Operating conditions
Electromagnetic emissions FCC Class A; EN 55022/CISPR 22 Class A; VCCI Class A Yes check.svg.png FCC Class A; EN 55022/CISPR 22 Class A; VCCI Class A
Operating Temperature Range 0 to 55° C Yes check.svg.png 0 to 55° C
Operating Humidity Range 15 to 95% non-condensing Yes check.svg.png 15 to 95% non-condensing
Dimensions / weight / warranty
Dimensions (w x d x h) 44.2 x 20.3 x 4.6 cm Yes check.svg.png 44.2 x 20.32 x 4.57 cm
Weight 2.7 kg Yes check.svg.png 2.72 kg
Warranty Lifetime warranty: for as long as you own the product, with next-business-day advance replacement (available in most countries) Yes check.svg.png Lifetime warranty: for as long as you own the product, with next-business-day advance replacement (available in most countries)

Analyse der Hardware

Unter der Vermutung, dass es sich bei den beiden Modellen um die gleiche Hardware handelt, welche auch beide mit der gleichen Software aktualisiert werden, müsste sich die Information des Modells in einem Flash Speicher finden lassen. Um diese Speicher zu finden, wurde die Hardware analysiert. Hier die Auflistung der betreffenden Bausteine:

Name Anzahl Position Hersteller Marking Wert Funktion Bemerkung
K4S643232E-TC60 3 U1, U3, U4 Samsung SAMSUNG 223 K4S643232E-TC60 UYD993DA KOREA - 8MB SDRAM macht insgesamt 24MB RAM
AM29LVO17D 1 U2 AM29LVO17D - 2MB Flash Speicher macht insgesamt 2MB ROM
Icon apps query.svg.png 1 BGA1 Icon apps query.svg.png Icon apps query.svg.png - ASIC+CPU vermutlich ASIC mit integriertem ARM7TDMI und den restlichen 2MB RAM intern

Weiteres Vorgehen

Icon apps query.svg.png Flash Speicher auslesen (dumpen). Evtl. mit On Borad Adapter für das TSOP Format des Flash ICs.
Icon apps query.svg.png Nach den Modelinformationen im Dump suchen
Icon apps query.svg.png Wenn gefunden: Ändern und umprogrammieren
Icon apps query.svg.png Wenn nicht 2512 finden und versuchen dessen Flash zu übertragen